beautypg.com

Gorman-Rupp Pumps SE2C3 115V 1P 1483930 and up User Manual

Page 15

background image

OM−06492

SE SERIES

PAGE C − 2

OPERATION

PUMP OPERATION

Liquid Temperature and Overheating.

Overheated pumps can cause severe
burns and injury. If the pump becomes
overheated:

1. Stop the pump immediately.
2. Make certain the control box or

switch is in the OFF or STOP posi-
tion, or that the power supply to the
control box has been otherwise cut
off and locked out to ensure that
the pump will remain inoperative.

3. Allow the pump to completely cool

if overheated.

4. Close the discharge valve (if

used).

5. Refer to instructions in this manual

before restarting the pump.

Do not start the pump more than 6 times
per hour. If the motor does not cool be-
tween starts it will overheat, resulting in
damage to the motor windings.

The maximum liquid temperature for this pump is
120

_F (490_C). Do not apply it at a higher operat-

ing temperature.

Overheating can occur if the pump is made to start
and stop repeatedly without time to cool off be-
tween starts, the liquid level is allowed to fall too
low to sufficiently cool the motor, or if the circuit
breaker or fuse fails to provide adequate protec-
tion. Operating the pump against a closed dis-
charge valve for an extended period will also cause
the pump to overheat.

Approach the pump cautiously after it
has been running. Although the motor is
cooled by the liquid being pumped, nor-
mal operating temperatures can be high
enough to cause burns. The tempera-
ture will be especially high if operated
against a closed discharge valve. Never
operate against a closed discharge
valve for long periods of time.

If overheating does occur, stop the pump immedi-
ately and allow it to cool before servicing it. Ap-
proach any overheated pump cautiously.

Overheated pumps can cause severe
burns and injuries. If overheating of the
pump occurs:

1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before ser-

vicing.

5. Vent the pump slowly and cau-

tiously

6. Refer to instructions in this manual

before restarting the pump.

Impeller Rotation

Check impeller rotation as follows before operation
to ensure that the impeller is rotating in the correct
direction.

While checking impeller rotation, secure
the pump to prevent the power cable from
coiling.

Suspend the pump from the lifting device fitted on
the pump.