beautypg.com

Pump maintenence and repair – Gorman-Rupp Pumps 04B3-F4L 1242057 thru 1316965 User Manual

Page 22

background image

0 SERIES

OM--01216

MAINTENANCE & REPAIR

PAGE E -- 1

PUMP MAINTENANCE AND REPAIR - SECTION E

MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.

STANDARD PERFORMANCE FOR PUMP MODEL 04B3--F4L

Based on 70_ F (21_ C) clear water at sea level

with minimum suction lift. Since pump installations
are seldom identical, your performance may be dif-
ference due to such factors as viscosity, specific
gravity, elevation, temperature, and impeller trim.

If your pump serial number is followed by an “N”,
your pump is

NOT a standard production model.

Contact the Gorman-Rupp Company to verify per-
formance or part numbers.

Never tamper with the governor to gain

more power. The governor establishes

safe operating limits that should not be

exceeded. The maximum continuous

operating speed for this pump is 2400

RPM.