Troubleshooting – Gorman-Rupp Pumps 16C2-F5L 1338631 and up User Manual
Page 19
OM−01876
10 SERIES
TROUBLESHOOTING
PAGE D − 1
TROUBLESHOOTING − SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man-
ual.
2. Switch off engine ignition and dis-
connect the positive battery cable
to ensure that the pump will re-
main inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau-
tiously.
7. Drain the pump.
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO PRIME
Not enough liquid in casing.
Suction check valve contaminated or
damaged.
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas-
ket.
Suction lift or discharge head too
high.
Strainer clogged.
Add liquid to casing. See PRIMING.
Clean or replace check valve.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leak-
ing or worn seal or gasket.
Check piping installation and install
bypass line if needed. See INSTAL-
LATION.
Check strainer and clean if neces-
sary.
PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gas-
ket.
Strainer clogged.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace
leaking or worn seal or gasket.
Check strainer and clean if neces-
sary.