beautypg.com

Gorman-Rupp Pumps 16C2-F5L 1338631 and up User Manual

Page 18

background image

10 SERIES

OM−01876

OPERATION

PAGE C − 4

ty shutdown features are pre-set at the
factory; do not attempt to adjust any of
the settings. Determine the cause of
shutdown before

putting the unit back

into service. Consult the factory for ad-
ditional information.

OPERATION IN EXTREME HEAT

The safety shutdown system will automatically
stop the unit if engine operating temperature ex-
ceeds design limits. If engine over-temperature
shutdown occurs, allow the unit to completely cool
before restarting.

If engine overheating continues, check the engine
lubricant level and viscosity. Consult the engine
operation manual for the recommended lubricant
for operation in extreme heat.

If the unit is equipped with the optional auto-start
control, the float(s) may need to be adjusted to al-
low shorter run and longer cooling periods, if pos-
sible.

If the pump is equipped with the option-
al automatic starting system, it is sub-
ject to automatic restart. Keep hands
and clothing away from the unit to pre-
vent injury during automatic operation.
Disconnect the battery before perform-
ing any maintenance. Failure to do so
may result in serious personal injury.

If the application involves a high discharge
head, gradually close the discharge
throttling valve before stopping the pump.

After stopping the pump, switch off the engine igni-

tion and remove the key

to ensure that the pump

will remain inoperative.

BEARING TEMPERATURE CHECK

Bearings normally run at higher than ambient tem-
peratures because of heat generated by friction.
Temperatures up to 160

_F (71_C) are considered

normal for bearings, and they can operate safely to
at least 180

_F (82_C).

Checking bearing temperatures by hand is inaccu-
rate. Bearing temperatures can be measured ac-
curately by placing a contact-type thermometer
against the housing. Record this temperature for
future reference.

A sudden increase in bearing temperature is a
warning that the bearings are at the point of failing
to operate properly. Make certain that the bearing
lubricant is of the proper viscosity and at the cor-
rect level (see LUBRICATION in MAINTENANCE
AND REPAIR). Bearing overheating can also be
caused by shaft misalignment and/or excessive vi-
bration.

When pumps are first started, the bearings may
seem to run at temperatures above normal. Con-
tinued operation should bring the temperatures
down to normal levels.

Cold Weather Preservation

In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any
remaining liquid that could freeze the pump rotat-
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con-
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre-
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.