beautypg.com

Alignment – Gorman-Rupp Pumps 16C2-F5L 1338631 and up User Manual

Page 14

background image

OM−01876

10 SERIES

PAGE B − 7

INSTALLATION

Air Release Valve Installation

The Automatic Air Release Valve must be inde-
pendently mounted in a horizontal position and

connected to the discharge line of the self-priming
centrifugal pump (see Figure 3).

DISCHARGE PIPE

DISCHARGE

CHECK VALVE

PUMP DISCHARGE

SELF-PRIMING

CENTRIFUGAL

PUMP

SUCTION

LINE

SUPPORT

BRACKET

CLEAN-OUT

COVER

INSTALL AIR RELEASE VALVE

IN HORIZONTAL POSITION

90

_ LONG

RADIUS

ELBOW

WET WELL

OR SUMP

BLEED LINE 1"
(25,4 MM) DIA. MIN.
(CUSTOMER FUR-
NISHED) EXTEND 6"
(152 MM) BELOW
PUMP OFF LIQUID
LEVEL

Figure 3. Typical Automatic Air Release Valve Installation

Connect the valve outlet to a bleed line which
slopes back to the wet well or sump. The bleed line
must be the same size as the outlet opening or
larger, depending on which Air Release Valve is be-
ing used. If piping is used for the bleed line, avoid
the use of elbows whenever possible.

NOTE

For multiple pump installations, it is recommended
that each Air Release Valve be fitted with an inde-
pendent bleeder line directed back to the wet well.
If multiple Air Release Valves are installed in a sys-
tem, do not direct bleeder lines to a common mani-

fold pipe. Contact your Gorman-Rupp distributor or
the Gorman-Rupp Company for information about
installation of an Automatic Air Release Valve for
your specific application.

ALIGNMENT

The alignment of the pump and the engine is criti-
cal for trouble-free mechanical operation. See Sec-
tion E, Securing Intermediate And Drive Assem-
bly To Engine for detailed information.