beautypg.com

Flow diagrams, Specifications, Legend – Pump Solutions Group Neptune Polymaster User Manual

Page 6

background image

Flow

Diagrams

Specifications

All Models Except PAD-3000R & PMD-3000R

Models PAD-3000R & PMD-3000R

1

Polymer Metering Pump

2

Injection/Check Valve

3

Gatlin Distribution Head

4

Water Pressure Gauge

5

Solenoid Valve

6

Dilution Water Adjusting Valve

7

Flowmeter

8

Water Differential Pressure Switch

9

Static Mixer and Viewing Cylinder

Legend

Minimum water pressure required: 1.7 bar (25 psi)
Maximum operating pressure:

6.9 bar (100 psi)

Pressure drop across unit less than: 1.0 bar (15 psi)

Turndown ratio:

Water

5:1

Polymer

2:1 on stroke length (most models)

10:1 on speed

20:1 total

Water control includes:

Rotameter for flow indication and adjustment

Solenoid valve for on/off control

Water pressure gauge

Water differential pressure switch

Water supply line strainer

Polymer control includes:

Positive displacement metering pump with manual stroke length

control and manual or automatic stroke speed control

Polymer inlet line strainer

Polymer injection check valve and back-pressure valve

Standard electrical controls include:

NEMA 4X control enclosure and junction box

Power cord and plug

Terminal strip connection for 4-20 mA pacing signal

(automatic units only)

Local-off-remote selector switch and red running light. Terminals

for remote start/stop interlock.

Interlock for shutdown on loss of dilution water includes local

amber fault light and remote alarm contact

Local manual override of polymer flow rate

Power requirements:

Specify: 1 phase, 115 volt, 60 Hz

OR 1 phase, 220 volt, 50 Hz

Solenoid pump models: 5 amps @ 115 volt

Motor-driven pump models: 15 amps @ 115 volt

6