XIII. Trouble Shooting Guide -
Separators
Trouble
Probable Cause
Corrective Action
Centrifugal Separators
Vacuum Producer Motor
– Leaks.
Check access doors for tightness. Check dirt
Overload
can or discharge valve sealing. Check for
holes worn in separator (when handling abrasive
materials.
Low Vacuum in System
– Leaks.
See above.
– Screen Clogged.
Clean screen (access through clean-out door
in side of Separator).
Majority of Material
– Leaks.
See above. A small leak will greatly affect
Not Being Collected
separation efficiency.
Tubular Bag Separators
Vacuum Producer Motor
– Leaks.
See above.
Overload
Low Vacuum in System
– Leaks.
See above.
– System Overload
See Vacuum Producer Trouble Shooting Guide
– Bags Clogged
Shake bags at more frequent intervals (only
shake bags when system is not running).
Air leaks blowing debris into filter eliminate leaks.
Dirt Passing Through
– Loose bag.
Check bags and re-install per instructions.
Separator and
Clogging Vacuum
– Holes in bags.
Carefully examine bags for holes and replace
Producer or Being
defective bags.
Exhausted
– Incorrect filter material.
Contact factory.
.