beautypg.com

Imetec BELLISSIMA FLASH & GO PLUS User Manual

Page 45

background image

EN

83

EN

82

9. Set the lowest power level when applying the first treatment. Follow the

instructions in the “Information before use” chapter if you wish to use a

different power level for follow-up sessions.

10. Apply the treatment surface (5A or 15A) firmly on the skin. Only when

the treatment surface (5A or 15A) is entirely in contact with the skin, the

ready-for-use LEDs (6A) start to flash.

11. Press the pulse activation button (3). The appliance immediately verifies

the skin colour: if the skin colour is fair enough for a safe application, the

appliance emits the light pulse on the skin together with a sound and

the ready-for-use LEDs (6) go off. A slight tingling sensation may be felt.

Note: if the appliance does not emit a light pulse and the skin colour check

LEDs (6A) flash, the skin tone is too dark for a safe application. Try to use

the appliance on another part of the body.

12. Remove the treatment surface (5A or 15A) from the treated area.

13. 3.5 seconds after the previous pulse is emitted, the ready-for-use LEDs

(6) light up again.

14. Move the treatment surface (5A or 15A) to another section. Use the pressure

marks left previously to place the treatment surface on the adjacent section,

avoiding overlapped pulses (See “Covering the entire treatment area”).

15. Repeat the process, starting from point 10, until the entire area to be

treated is covered.

AFTER TREATMENT

16. Press the switch-on/stand-by button (10): all the LEDs that are on, go off

and the stand-by LED lights up (9).

17. Remember the power level used for the treatment session as this will be

reset when the appliance is next switched on.

18. Disconnect the adapter cable (14) from the socket.
Caring for the skin after the hair removal session.
See “Other precautions for safe use”.
TREATMENT WITH THE PRECISION LAMP

If you wish to use the precision lamp (15) for smaller areas or where more

precision is required, proceed as follows:

• Before applying the precision lamp (15), emit a light pulse in the area that

is to be treated with the standard lamp (5), following the user instructions

from 7 to 12. This will allow the skin colour sensor (5B) to verify the tone

of the skin that is to be treated and prevent the pulse from being emitted

if it is too dark.

• Press the switch-on/stand-by button (10) after emitting a pulse: the switch-

on LED (11) goes off and the standby LED (9) goes on.

• Remove the lamp (5) from the handpiece by

grasping and pulling it gently upwards to release it.

• Insert the precision lamp (15) into the handpiece

by pressing gently.

• Follow the user instructions from point 7 to point

18, being careful not to go over the area previously covered by the emitted

pulse of the standard lamp (5).

• The procedure must be repeated every time the power cord (14) is

disconnected from the socket.

This manual is related to the following products: