beautypg.com

Imetec BELLISSIMA ZERO User Manual

Page 40

background image

EN

77

EN

76

SKIN COLOUR SENSOR (1B)

Using the pulsed light epilation system on dark skin can cause adverse effects

such as burns, blisters and changes in the colour of the skin (hyper or hypo-

pigmentation).

The appliance has a skin colour sensor (1B) that measures the tone of the

skin in the area that is to be treated at the beginning of each session and

occasionally during the session.

If the skin colour sensor (1B) detects a complexion that is too dark for the

treatment, the appliance stops emitting the light pulses automatically and the

skin colour/device-is-ready LED (5C) starts to flash rapidly.

If this occurs, try to use the appliance on another part of the body or contact

the IMETEC service centre.
THE TWO AppLICATION METHODS

The device can be applied in two ways: “by Pulse” and “Sliding”.
By pulse Method

The by pulse method is optimal when using higher power levels as it allows for

better control of the skin areas being covered. Each time the pulse activation

button is pressed (2), a light pulse is emitted.

A precise technique must be followed when using the by pulse method to

make sure the entire treatment area is covered and dangerous overlapped

pulses are prevented:

• Imagine the treatment area is divided in rows.

• Emit a light pulse proceeding in order, starting from one end of each row

and continuing to the other end (from the bottom upwards or right to left,

depending on the treatment area).

The area covered by the treatment surface (1A) leaves temporary marks on

the skin due to the light pressure applied by the handpiece.

These marks remain visible for a few moments and are useful to establish the

subsequent pulse position.
Sliding Method

The Sliding method is optimal when using low power levels and it allows for

faster and more efficient sessions. When using the Sliding method, keep

the pulse activation button (2) pressed and slide the device in a slow gliding

motion while remaining in contact with the skin, along the area to be treated.

At lower power levels (1 and 2), the device takes only 1 to 1.5 seconds to

recharge between one pulse and another, thereby allowing an uninterrupted

sequence of flashes.

ATTENTION

Do not overlap the pulses!

Do not treat the same section of skin more than once per hair removal session!

STOP USING THE APPLIANCE IMMEDIATELY if excessive heat or tingling

is felt or blisters or small burns appear on the skin!