Operation, Front panel controls and indicators – Extron Electronics MTP 1500RL 15HD RS SEQ User Guide User Manual
Page 14
Operation
This section describes the operation details for the MTP 1500RL RS SEQ receiver. It covers:
z
Front Panel Controls and Indicators
z
z
Front Panel Controls and Indicators
Front panel features are shown below.
MTP 1500RL SERIES
RGB
PEAKING
LEVEL
DELAY
RED
GREEN
BLUE
SELECT
ADJUST
MIN/MAX
5
1
2
4
3
6
Figure 8.
MTP 1500RL 15HD RS SEQ Receiver Front Panel
a
Power LED — Indicates power is applied to the MTP.
b
Select button — This recessed button selects the red, green, or blue video signal to
adjust, and resets all them to a skew delay of zero nanoseconds.
Press and release this button to cycle through and select the red, green, or blue video
signal for adjusting. The selected signal is indicated by the Red, Green, and Blue LEDs
(
c
).
Press and hold the button in for approximately 3 seconds to zero the skew delay for red,
green, and blue. The Red, Green, and Blue LEDs (
d
) all turn off. Release the button.
NOTE: The SEQ receiver automatically saves the setting for the video signal that is
being deselected when this button is pushed or when the selection times
out after 10 seconds.
c
Red, Green, and Blue LEDs — These LEDs indicate the video signal that is selected by
the Select button (
b
) for skew adjustment using the Adjust control (
d
). The LED for the
selected color blinks when the skew compensation for the video signal of the selected
color has reached the minimum or maximum limit.
MTP 1500RL 15HD RS SEQ • Operation
8