Installation and

Setup

This section describes how to connect applicable cables to the MTP 1500RL 15HD RS SEQ
receiver.

It covers:

z

Rear Panel Features

z

Power Supply Wiring

z

TP Cable Termination

Rear Panel Features

The illustration below shows the rear panel of the MTP 1500RL 15HD RS SEQ receiver.

INPUT

BUFFERED OUTPUT

POWER

12V

1.0A MAX

MTP 1500RL 15HD RS SEQ

MTP

RS-232

Rx

Tx

OUTPUT

MTP

ON

H +

V +

CSYNC

SOG

VIDEO

END

BI-232

MTP

MTP

5

6

1

2

4

3

Figure 3.

MTP 1500RL RS SEQ Receiver Rear Panel Features

a

Power connector — Plug the included external 12 VDC, 1 A, power supply into this

2-pole captive screw connector. See “

Power Supply Wiring” section

for wiring details.

CAUTIONS: • Always use a power supply supplied or specified by Extron. Use of an

unauthorized power supply voids all regulatory compliance certification
and may cause damage to the supply and the end product.
• Unless otherwise stated, the AC/DC adapters are not suitable for use in
air handling spaces or in wall cavities.
• The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and the
Canadian Electrical Code part 1, section 16.
• The power supply must not be permanently fixed to building structure
or similar structure.

b

Input connector — Connect one end of the twisted pair cable from an MTP transmitter

to this RJ-45 connector (see

“TP Cable Termination”

to wire the connector).

CAUTION: Do not connect these devices to a computer data or telecommunications

network.

c

Buffered output connector — Connect up to 5 daisy-chained MTP receivers to

this RJ-45 connector.

MTP 1500RL 15HD RS SEQ• Installation and Setup