MPS Switcher Error Responses

When the MPS switcher receives an SIS command and determines that it is valid, it
performs the command and sends a response to the host device. If the switcher is unable
to perform the command because the command is invalid or contains invalid parameters, it
returns an error response to the host. The error response codes are:

E01

]

— Invalid input channel number (too large)

E10

]

— Invalid command

E13

]

— Invalid value (out of range)

Command and Response Table

Using the Command and Response Table

The command and response table is shown on the following pages. Symbols are used
throughout the table to represent variables in the command and response fields. Symbol
definitions and an ASCII-to-hexadecimal (HEX) conversion table are shown below.
Command and response examples are shown throughout the table.

NOTE: Upper and lower case text can be used interchangeably unless otherwise stated.

ASCII to Hex Conversion Table

Space

Symbol definitions

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

|

or

}

= Carriage return (no line feed, hex 0D)

= Space character in command or response (all other spaces shown are for clarity)

W or

E

= Escape key (hex 1B)

X!

= HDMI/DTP audio output select

0 = Embedded audio
1 = Analog audio

X@

= Video output select

1 = RGB
2 = HDMI/DTP

X#

= Status

0 = off/disabled, 1 = on/enabled

X$

= Mic gain in 1 dB steps

0 to 60

X%

= Mic attenuation in 1 dB steps

1 to 18

X^

= Mic level in 1 dB steps

– 18 to +60,

X*

= Mic talk-over threshold level in dB

0 to 30, default = 8

X1)

= Program volume adjustment range

0 to 100

MPS 602 • Remote Communication and Control