Extron Electronics MSV0502 User Manual
Page 15
11
2002 - INLINE, INC.
MSV0502 OPERATION MANUAL - v1.0 4/26/02
Creating Presets
Once you create a switch or patch through the Output-Input method, you can assign it a Preset number.
This is a valuable, timesaving feature and allows unskilled operators the ability to duplicate complex
patches without having to actually configure the patch.
To create a preset:
1. Create the desired configuration of input/output connections.
2. Press
the
Preset button.
3. Press any one of the Input or Output select buttons to pick a storage location for this preset.
4. Be sure to label or notate each Preset you make.
5. To recall a preset, press the Preset button, followed by the input/output button where the preset
was stored.
Key Concept
When you turn the MSV0502 on, it uses setup #1 as the default, and this cannot
change. If you plan on turning off the MSV0502, make certain to store the initial
settings in setup #1.
Power-on Settings
To power the MSV0502 up, simply plug the unit it the outlet. There is no power on/off switch.
Reset to Factory Default
Soft Reset - To restore I/O configurations, volume levels, and the serial set up to the default factory
setting, press the 1 and 5 input buttons.
Hard Reset - To restore all parameters, including presets, to the default factory setting, use the [DFLTx]
command.