Introduction, cont’d
1-4
5
.
Reliable earthing (grounding)
— Reliable earthing
of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).
Rack mount the unit using an optional Extron 2U universal rack
shelf (Extron part #60-032-01), as follows:
1
. Remove rubber feet if they were previously installed on
the bottom of the unit.
2
.
Place the DA on one side of the optional 2U (two unit high,
19" wide) rack shelf (Extron part #60-032-01). Align the
front of the DA with the front of the shelf, and align the
threaded holes on the bottom of the DA with the holes in
the rack shelf.
3
.
Secure the DA to the rack shelf with the two provided
4-40 x 3/16" machine screws. Insert the screws from the
underside of the shelf, and securely fasten them through
diagonally opposite corners.
4
.
Fasten the false front panel (provided with the rack shelf)
to the unoccupied side of the rack (as shown below), or
install a second half-rack-width device in that side by
repeating steps 1 through 3.
5
.
Secure the rack shelf to the rack using four 10-32 x ¾" bolts.
Insert the bolts through #10 beveled washers, then through
the holes in the mounting brackets.