Extron Electronics DVI 201xi Tx User Guide User Manual
Page 18
![background image](/manuals/311699/18/background.png)
6.
Boot up the source device. The source boots with the resolution and refresh rate of the
local monitor.
7.
Power on the display device.
NOTE: The remote display device must be capable of handling a resolution equal to
or greater than that of the local monitor.
Using Pass-through Mode with DDC Routed to the Remote Display
NOTE: Although DDC can be routed to the remote display, there may be instances
when the signals may become corrupted or weak. In those cases, the source
device may be unable to boot up correctly.
1.
Set the EDID Minder switch to the Off (Down) position and the Remote DDC switch to
the On (Up) position (see the figure at right). The position of the Default
EDID switch is not relevant.
2.
Connect the source device to the transmitter input.
3.
Connect the display device to the receiver output and, if required, the local
monitor to the transmitter output.
4.
Connect the transmitter to the receiver with the two twisted pair cables.
z
z
Transmitter port 1 connects to receiver port 1
z
z
Transmitter port 2 connects to receiver port 2
5.
Power on the remote display.
6.
Boot up the source device. The source boots with the resolution and refresh rate of the
remote display.
NOTE: The local monitor is the source of EDID and must be powered on before the
source device is booted.
7.
Power on the display device.
NOTE: If used, the local monitor must be capable of handling a resolution equal to
or greater than that of the remote display.
ON
1 2 3
ON
OFF
DEF
AUL
T EDID
EDID MINDER
REMOTE DDC
DVI 201xi Tx • Configuration and Operation