1.
Cut the cables to the required length. Both cables should be the same length.
2.
Remove about 7/8 inch (2.2 cm) of the outer coat. If using STP cable, peel back the
shielding and fold it over the top of the outer coat.
Peel back shield and
Fold back.
Figure 6.
Terminating Cable (1)
3.
Cut away and discard the clear cellophane inner wrapper that extends beyond the
folded back shielding.
4.
Cut a piece of self-adhesive shielded aluminum tape, remove the backing, and wrap
it around the folded back shielding. The tape should slightly overlap the end of the
shielding.
Aluminum Tape
Wrap tape around folded foil shielding.
(cut and save a portion for the
crimped connector tangs)
Figure 7.
Terminating Cable (2)
5.
Separate the individual wires, and arrange them so that all eight wires are side by side
in the same order as the T586A or T586B standard shown below. Both ends of a cable
must be wired to the same standard (T586A or T586B).
Pin # TIA/EIA
T 586 A
Wire color
TIA/EIA
T 586 B
Wire color
Cable 1
Cable 2
1
White-green
White-orange
Data 0+
CEC
2
Green
Orange
Data 0-
HPD
3
White-orange
White-green
ID Clock+
RS-232 Tx
4
Blue
Blue
Data 1+
DDC Clock
5
White-blue
White-blue
Data 1-
+12 V
6
Orange
Green
ID Clock-
RS-232 Rx
7
White-brown
White-brown
Data 2+
DDC Data
8
Brown
Brown
Data 2-
Ground
6.
Feed the wires into the RJ-45 connector (see the figure above
right) and crimp the cable in the normal manner (see figure 7),
folding the tangs of the connector over the shielded tape.
Crimped Connector
Figure 8.
Terminating Cable (3)
Side
12345678
Insert
Twisted
Pair Wires
Pins:
RJ-45
Connector
DVI 201xi Tx • Panel Features and Connections
8