MULTI-UNIT SYSTEM

Multiple T-H3-DV / 540H units can be combined for a multi-unit system, along with the multi-unit

controller (TM-MC02). The multi-unit controller can control 2 to 20 units. For a 20 unit system,

the computer can modulate between the usages of 13,000 BTU/h (Propane) or 15,000 BTU/h

(Natural gas) to 4.0 Million BTU/h.

An individual cut-off switch is recommended for each unit in a multi-unit system for the purpose

of maintenance.

Multi-unit system connection diagram

Multi-unit controller with the remote controller wiring:

• T

he dark squares should not need adjustment.

• T

his is the connection diagram between T-H3-DV / 540H and multi-unit controller

for 2 to 20 water heaters. Above is a sample for 3 water heaters.

• T

he multi-unit controller automatically allocates the unit # (1-20) to each water

heater that is part of the multi-unit system.

• In a multi-unit system, connect the “[1]” connector and the “[2]” connector with

the communication cable (Refer to p. 27) or 18 gauge wire cables. The total cable

length can be up to 76.2 m (250 ft.) long.

For detailed instructions on the multi-unit controller, refer to the

instructions that are packaged with the multi-unit controller.

OFF

ON

1

1

1

2

2

2

PARENT

PARENT

PARENT

1

2

3

4

5

6

Connectors

Connectors

Connectors

OFF

ON

OFF

ON

Lower bank of

DIPswitches

Lower bank of

DIPswitches

Lower bank of

DIPswitches

1

2

3

4

5

6

1

2

3

4

5

6

Communication cable

Remote controller cable

Unit 1

Unit 2

Unit 3

Remote controller

Terminals for

water heaters

TM-MC02

Remote controller

terminals

Cold IN

Hot Out

T-H3-DV / 540H

TM-MC02

Installation

Installation Manual