Exhaust vent (stainless steel vent), Installation installation manual – John Wood Takagi - 240H-340H-540H User Manual

Page 16

background image

16

Page

76 mm (3") vent connection Diagram

From 76 mm (3") to 102 mm (4") vent connection Diagram

-Exhaust vent (Stainless steel vent)-

This is a Category IV appliance and must be vented accordingly. The vent system must be sealed airtight.

All seams and joints without gaskets must be sealed with high heat resistant silicone sealant or UL listed

aluminum adhesive tape having a minimum temperature rating of 71 °C (160 °F). For best results, a vent

system should be as short and straight as possible.

• These models are a Category IV appliance and must be vented accordingly with any 4” vent

approved for use with Category III/IV or Special BH type gas vent.

The manufacturer recommends the “T-Vent” line manufactured by TAKAGI. (Refer to Takagi’s

“T-Vent” brochure for details.) However, the following are also UL listed manufacturers: ProTech

Systems Inc. (FasNSeal), Flex-L Inc., Z-Flex Inc. (Z-Vent III), Metal-Fab Inc., and Heat-Fab Inc. (Saf-T

Vent).

Follow the vent pipe manufacturer’s instructions when installing the vent pipe.

Do not common vent this appliance with any other vented appliance. (Do not terminate vent

into a chimney. If the vent must go through the chimney, the vent must run all the way through

the chimney with Category III / IV approved or Special BH vent pipe.)

• The maximum length of exhaust vent piping must not exceed 30.5 m (100 ft.) (deducting 1.5 m

(5 ft.) for each elbow used in the venting system). Do not use more than 5 elbows.

• When the horizontal vent run exceeds 1.5 m (5 ft.), support the vent run at 0.9 m (3 ft.) intervals

with overhead hangers.

Installation

Installation Manual

76 mm (3”)

plastic socket

Exhaust vent collar

(Female)

76 mm (3”)

plastic straight pipe

76 mm (3”)

plastic socket

Intake vent collar

(Female)

76 mm (3”)

plastic straight pipe

1.  Connect a 76 mm (3") plastic socket

directly on the exhaust and intake vent

collar of the water heater.

2.  Connect a 76 mm (3”) plastic straight

pipe to the plastic socket.

1.  Connect a 76 mm (3") x 102 mm

(4") plastic reducer directly on the

exhaust and intake vent collar of

the water heater.

2.  Connect a 102 mm (4”) plastic

straight pipe to the reducer.

102 mm (4”)

plastic straight pipe

76mm (3") x 102 mm (4")

plastic reducer

Exhaust vent collar

(Female)

Intake vent collar

(Female)

102 mm (4”)

plastic straight pipe

76mm (3") x 102 mm (4")

plastic reducer