Xylem WL16 WATER LEVEL LOGGERS User Manual
Page 9

Global Water
800-876-1172 • globalw.com
- 9 -
VII. Direct Connection:
8) To confirm the installation, look in the
Device Manager and find the USB Serial
Port. The COM setting following that will
show the virtual COM port that has been
automatically assigned to the driver. As
you will see in the following sections, this
COM port will be automatically detected
by the Global Logger software so it is not
necessary to note which port is being
used by the driver.
Important: This data logger supports an Auto Baud Rate Mode which automatically
detects the communication speed. However; this communication software also
supports loggers which may be programmed in a Fixed Baud Rate Mode. This is
useful in telemetry applications, particularly when using Global Water data loggers
with our Global Access radio modem software. The upcoming discussion assumes
that the logger is programmed in auto detect mode. If you cannot connect to the
logger and suspect that the logger may be using a fixed rate mode; try each
connection speed separately, especially 38400 which is required when using the
Global Access software.
There are 3 ways to connect to the WL16 data Loggers, direct connection through
the RS-232 serial port (WL16S only) or USB port (WL16U only), as well as dial out
through an installed modem (requires WL16S only with external serial modem).