beautypg.com

Iv. specification – Xylem PL200-H HYDRANT WATER PRESSURE LOGGERS User Manual

Page 4

background image

Global Water

800-876-1172

globalw.com

- 4 -

IV.

Specification:

Power Supply:

One 3.6 Volt, 2.4Ahr, AA Size Lithium Battery

Global Water Part number 01-678

or from mouser.com, part number 667-TL5903S

Operating Temperature

Industrial, -40ºC to +85ºC

Pressure Sensor:

0-200 psi gauge type sensor

300 psi over-pressure

Accuracy, +/- 1%, full scale

Battery voltage monitor

Analog Resolution: 12-Bit, 4096 Steps

Sensor Warm-up Time: 0 Seconds (50mS Actual)

Sample Modes:

Fixed Interval: Programmable from 1 Sec. to >1 Year

High Speed: 10 Samples per second

Logarithmic Sample Rate (Approximation)

Exception (Log only on deviation from previous reading)

Storage Capacity:

81,759 Recordings of water pressure and battery

voltage with date/time stamp

Communication Ports:

USB Type B

Selectable Baud Rates: Auto detect or fixed rates at

9600, 19200, 28800, 38400, 57600, 115200

57.6K Baud is recommended

Thread Size:

PL200-H-1: 2.5” BSP Male

PL200-H-2: 2.5” NHT Female

Spanner Wrench:

Optional, 95-100mm

Part Number 01-827

Optional Adaptors:

2.5” BSP Female to 2.5” NHT Female

Part Number 01-826

Call for other available adaptors