- 11 -

COM Status: This reads “Connected” in green or “Not Connected” in red,

depending on the current connection status.

Logger Name: The logger name is a user defined name associated with a particular

logger to identify one from another. It is programmed in the Setup menu as

described later and is limited to 32 characters.

Logger Time: The time and date displayed is that of the real-time clock in the

logger. It is only updated upon initial connection and certain functions that cause

data to be read from the logger. These include Sample Continuously, Get Sample,

Sync Time and Setup whose functions are to be described later.

Interval: This field displays the logging mode. “Fast” indicates high-speed mode

and “Logarithmic” is shown in logarithmic mode. If the logger is in the normal fixed

interval sampling mode, the time between samples will be displayed. These modes

are to be described later.

Warmup: This displays the sensor warm-up time, generally 3 seconds.

Records: This field indicates the number of data recordings in memory.

Logging State: This shows whether the data logger is currently logging or waiting to

be started or stopped by the alarm timers. These features are described in detail

later.