3-2 SDI-12 Command and Response Protocol

H-4280

3.1 Master SDI-12 Command List

Standard SDI-12 commands

Command

Description

aM!

Make Measurement

aC!

Make Concurrent Measurement

aD0! and aD1!

Send Data

aV!

Verify Sensor

aI!

Send Identification

Extended SDI-12 commands unique to the H-4280

Command

Description

aAn!

Change sensor address

aXRCn!

Read configuration of channel n

aXWCn!

Write configuration of channel n

aXSCSn ddd!

Set current “stage” of channel n

aXRSn!

Read Slope of channel n

aXWSn ddd!

Write Slope of channel n

aXROn!

Read Offset of channel n

aXWOn ddd!

Write Offset of channel n

aXRMC!

Read Mean_Count

aXWMCnnn!

Write Mean_Count

aXRPM!

Read Power_Mode

aXWPMn!

Write Power_Mode

aXRWT!

Read Warmup_Time

aXWWTnnn!

Write Warmup_Time

aXTEST!

Initiate a repeating test printout