Xylem IM226R02 CP-Series Submersible Motors User Manual
Page 17

CP-Series Submersible Motors Installation, Operation and Maintenance Manual
15
TABLE 2 — 8" Three Phase Motors, 380 and 460 volt
Motor
Rated Rated
Operating Characteristics
Direct On-Line Service SF
SF
Type
Power Voltage
At Rated Power
Starting
Factor Watts Amps
Three HP kW V kW A RPM EFF PF Is Ts Tmax SF kW A
Phase
/In
/Tn
/Tn
P8..40T386A
40 30
380
37.0
67.8
3470 81.5 0.83 5.50 1.04 2.22 1.15 43.0
78.0
P8..40T466A
460
56.0
64.4
P8..50T386A
50 37
380
45.6
83.5
3475 81.5 0.83 5.26 1.04 2.23 1.15 53.5
96.1
P8..50T466A
460
69.0
79.4
P8..60T386A
60 45
380
54.2
99.3
3480 83.0 0.83 4.98 0.98 2.22 1.15 62.0
114
P8..60T466A
460
82.0
94.3
P8..70T386A
70 52
380
62.7
116
3475 83.0 0.82 5.56 1.06 2.22 1.15 73.0
134
P8..70T466A
460
96.0
110
P8..75T386A
75 55
380
66.1
121
3475 83.5 0.83 5.44 1.06 2.24 1.15 77.5
139
P8..75T466A
460 100 115
P8..80T386A
80 60
380
71.6
130
3480 84.0 0.84 5.07 1.04 2.23 1.15 83.0
149
P8..80T466A
460 107 123
P8..90T386A
90 67
380
80.0
146
3480 84.0 0.83 5.13 1.03 2.23 1.15 95.0
168
P8..90T466A
460 121 139
P8..100T386A
100 75
380
89.7
162
3485 84.0 0.84 5.04 1.01 2.22 1.15 108
187
P8..100T466A
460 134 154
P8..110T386A
110 83
380
99.1
179
3485 84.0 0.84 4.79 0.97 2.28 1.15 118
206
P8..110T466A
460 148 170
P8..125T386A
125 93
380
111
201
3490 84.0 0.84 4.60 1.02 2.22 1.15 129
231
P8..125T466A
460 166 191
Ts/Tn = ratio between starting torque and nominal torque.
Is/In = ratio between starting and FL amps.
Tmax/Tn = ratio between maximum torque and nominal torque.
TABLE 3 — 10" Three Phase Motors, 380 and 460 volt
Motor
Rated Rated
Operating Characteristics
Direct On-Line Service SF
SF
Type
Power Voltage
At Rated Power
Starting
Factor Watts Amps
Three HP kW V kW A RPM EFF PF Is Ts Tmax SF kW A
Phase
/In
/Tn
/Tn
P10..125T386A
125 93
380
110
199
3510 85.0 0.84 5.55 1.02 2.22 1.15 130
229
P10..125T466A
460 164 189
P10..150T386A
150 110
380
131
242
3520 85.5 0.82 6.38 1.43 2.19 1.15 149
272
P10..150T466A
460 200 225
P10..175T386A
175 130
380
152
286
3520 85.5 0.81 6.31 1.50 2.22 1.15 174
328
P10..175T466A
460 236 271
P10..200T386A
200 150
380
176
329
3525 85.5 0.81 6.24 1.56 2.22 1.15 191
379
P10..200T466A
460 272 313
Ts/Tn = ratio between starting torque and nominal torque.
Is/In = ratio between starting and FL amps.
Tmax/Tn = ratio between maximum torque and nominal torque.
Operation (continued)