Pump ser vice instructions for 609pf (watchman, Centrifugal pumps – Bell & Gossett DN0154D HS Vented Condensate Units Series HSTM User Manual
Page 5

5
These close coupled vertical centrifugal pumps are equipped
with mechanical seals. If system has not been properly cleaned
prior to installation of pump, foreign matter such as dirt, pipe
scale, core sand, etc. may clog the impeller and damage the
seal. A strainer is recommended in return line to pump.
Pump
must not be operated dry.
Seals may be damaged
if operated
without water present.
1. Close inlet line gate valve and operate pump momentarily
to remove as much liquid as possible from pump. Close
discharge line gate valve.
2. Shut-off and lock-out power.
3. Disconnect wiring to motor.
4. Make sure unit is cool enough that pump can be handled
safely. Open receiver drain to remove remaining liquid.
5. Loosen the motor to pump volute fasteners. Assure that
pressure is relieved per caution note.
6. Remove four capscrews (7) holding pump case to motor
and lift motor and impeller out of pump case.
7. Remove pump/motor assembly and place on work bench.
8. Hold top end of motor shaft with large screwdriver via
screwdriver slot in shaft and back of impeller (counter-
clockwise) with a rectangular bar or other flat tool inserted
between the vanes of the impeller.
9. Remove the rotating part of the mechanical seal from the
end of the shaft.
10. Remove seal holder (2) with stationary ceramic part of
mechanical seal and cup rubber from the end of the shaft.
11. Remove stationary ceramic part of mechanical seal and
cup rubber from recess in seal holder.
12. To install new seal, proceed as follows: Clean recess in seal
holder thoroughly. Orient motor so that conduit opening on
motor is to the left when looking at motor shaft. Replace
seal holder on the face of the motor maintaining concen-
tricity with motor face. Place new ceramic part of seal in the
cup rubber over motor shaft and press firmly into recess of
seal holder by hand, making certain both parts bottom
evenly. If assembly cannot be bottomed with fingers place
a wooden or cardboard tube over shaft onto ceramic and
push into place. Using a clean, lint-free cloth, wipe the mat-
ing surfaces of the seal clean of any foreign matter. Moisten
the carbon section of the rotating part of the seal and place
onto shaft to seat against the ceramic. Place seal spring
onto shaft.
13. Hold motor shaft as described in #8 and replace the
impeller on the shaft (clockwise rotation) making sure it is
tight.
14. Orient motor for pump reassembly with conduit opening to
the left. When mounting the pump case, discharge should
be 90˚ to the right of the conduit opening on motor. Use
care to insure tight gasket fit to prevent water leakage.
15. Replace four capscrews (7). Tighten down capscrews
evenly to avoid damage.
16. Reconnect pump bleed line (where applicable) and motor
wiring.
17. Close drain and slowly open inlet valves. See warning.
18. Jog to check motor rotation. See caution.
19. Observe operation thru several cycles.
1. Motor
2. Seal Holder
3. Seal
4. Impeller
5. Gasket
6. Case
7. Capscrew
(motor to
volute)
8. Wear Ring
9. Pipe Plug
10. Slinger
W
ARNING: EXPLOSIBLE
Do not pr
essurize receiver. Isolate receiver during leak
test. Do not plug overflow. Do not restrict vent opening to
atmosphere. Open valves slowly. Failure to follow these
instructions could result in serious injury or death.
W
ARNING: HIGH VOLTAGE
Disconnect and lock out power befor
e connecting or
servicing unit. Failure to follow these instructions could
result in serious injury or death.
CAUTION: PRESSURIZED SYSTEM
Operating system may contain very hot water under
pressure. Close inlet and open drains before servicing.
When servicing,
loosen scr
ews and move components to
assure pressure is relieved before
r
emoving
scr
ews. Keep
drains open during servicing. Failure to follow these
instructions could result in injury or property damage.
CAUTION: DO NOT RUN DR
Y.
SEAL DAMAGE MAY OCCUR.
Inspect pump seal r
egularly for leaks. Replace as
required. Failure to follow these instructions could result in
injury or property damage.
CAUTION: DO NOT REVERSE
Reverse operation can cause extensive damage to
pumps. Jog the motor to test for direction of rotation.
Failure to follow these instructions could result in injury or
property damage.
PUMP SER
VICE INSTRUCTIONS FOR 609PF (WATCHMAN
®
) CENTRIFUGAL PUMPS
CAUTION: HOT SURFACES
Surfaces ar
e hot when system is in operation. Do not
touch hot receiver, let unit cool before servicing. Failure to
follow these instructions could result in injury or property
damage.
1
10
7
3
4
8
6
9
5
2
FIG. 2
2DPF01