Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Characteristic Symbol
Min
Typ
Max
Unit Test
Condition
Output Voltage (Note 12)
V
OUT
10.8 12 13.2 V
V
IN
= 48V, I
OUT
= 15mA
Line Regulation (Notes 12 & 13)
∆V
OUT
— 240 750 mV
V
IN
= 15 to 72V , I
OUT
= 15mA
Temperature Coefficient
∆V
OUT
/∆T
— 8.0 —
mV/°C
T
J
= -40°C to +125°C
V
IN
= 48V, I
OUT
= 15mA
Load Regulation (Notes 12 & 14)
∆V
OUT
—
-450
-600
-600
-750
mV
I
OUT
= 0.1 to 30mA, V
IN
= 48V
I
OUT
= 0.1 to 100mA, V
IN
= 48V
Minimum Value of Input Voltage Required
to Maintain Line Regulation
V
IN(MIN)
15 — — V
—
Quiescent Current
I
Q
—
240
590
400
900
µA
V
IN
= 48V, I
OUT
= 10µA
V
IN
= 100V, I
OUT
= 10µA
Power Supply Rejection Ratio
∆V
IN
/∆V
OUT
—
45
—
dB
C
OUT
= 100nF, I
OUT
= 15mA,
V
OUT
= 12V, V
IN
=15 to 100V, f=100Hz
Notes:
12. Measured under pulsed conditions. Pulse width ≤ 300μs. Duty cycle ≤ 2%.
13. Line regulation
∆V
OUT
= V
OUT
(@ V
IN
= 72V) – V
OUT
(@ V
IN
= 15V)
14. Load regulation
∆V
OUT
= V
OUT
(@ I
OUT
= 30mA) – V
OUT
(@ I
OUT
= 0.1mA)
∆V
OUT
= V
OUT
(@ I
OUT
= 100mA) – V
OUT
(@ I
OUT
= 0.1mA)
Typical Application Circuit
Pin Functions
Pin Name
Pin Function
Notes
V
IN
Input Supply
To maintain output regulation, the input voltage can vary from 15V to 100V with respect to the GND pin. It
is recommended to connect a 1µF capacitor to GND.
GND
Power Ground
This pin should be tied to the system ground.
V
OUT
Voltage Output
Outputs a regulated 12V. It is recommended to connect a 10µF capacitor to GND. Minimum of 10µA must
be drawn from V
OUT
to maintain regulation. The pin can be pulled high to a maximum of 18V with respect to
ground.