Maximum ratings (per leg), Thermal characteristics (per leg), Electrical characteristics (per leg) – Diodes MBRF10100CT User Manual
Page 2
MBR10100CT / MBRF10100CT
Document number: DS36378 Rev. 8 - 2
2of 5
www.diodes.com
December 2013
© Diodes Incorporated
MBR10100CT / MBRF10100CT
ADVANCED INFORMATION
Maximum Ratings (Per Leg)
(@T
A
= +25°C, unless otherwise specified.)
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic Symbol
Value
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
RM
100 V
Average Rectified Output Current (Per Leg)
(Total)
I
O
5
10
A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load
I
FSM
110 A
Thermal Characteristics (Per Leg)
Characteristic Symbol
Value
Unit
Typical Thermal Resistance, Junction to Case (Note 5)
Package = TO-220AB
Package = ITO-220AB
R
θJC
4
6
°C/W
Typical Thermal Resistance, Junction to Ambient (Note 5)
Package = TO-220AB
Package = ITO-220AB
R
θJA
16
30
°C/W
Operating and Storage Temperature Range
T
J
, T
STG
-55 to +175
°C
Electrical Characteristics (Per Leg)
(@T
A
= +25°C, unless otherwise specified.)
Characteristic Symbol
Min
Typ
Max
Unit
Test
Condition
Forward Voltage Drop
V
F
—
—
0.79
—
0.84
0.72
V
I
F
= 5A, T
A
= +25°C
I
F
= 5A, T
A
= +125°C
Leakage Current (Note 6)
I
R
—
—
—
—
0.05
10
mA
V
R
=100V, T
A
= +25°C
V
R
= 100V, T
A
= +125°C
Notes:
5. Device mounted on heatsink (45mm x 20mm x 12mm), with minimum recommended pad layout per http://www.diodes.com.
6. Short duration pulse test used to minimize self-heating effect.