Maximum ratings, Thermal characteristics, Electrical characteristics – Diodes B270 - B2100 User Manual
Page 2

B270 - B2100
Document number: DS30021 Rev. 11 - 2
2 of 4
September 2011
© Diodes Incorporated
B270 - B2100
Maximum Ratings
@T
A
= 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic
Symbol
B270
B280
B290
B2100
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
70
80
90
100
V
RMS Reverse Voltage
V
R(RMS)
49
56
63
70
V
Average Rectified Output Current
@ T
T
= 125
°C
I
O
2.0
A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load
I
FSM
50
A
Thermal Characteristics
Characteristic
Symbol
Value
Unit
Typical Thermal Resistance Junction to Terminal (Note 4)
R
θJT
15
°C/W
Operating and Storage Temperature Range
T
J,
T
STG
-65 to +150
°C
Electrical Characteristics
@T
A
= 25°C unless otherwise specified
Characteristic
Symbol
Min
Typ
Max
Unit
Test Condition
Forward Voltage Drop
V
F
-
-
0.79
0.69
V
I
F
= 2.0A, T
A
= 25
°C
I
F
= 2.0A, T
A
= 100
°C
Leakage Current (Note 5)
I
R
-
-
-
-
7.0
2.0
μA
mA
@ Rated V
R
, T
A
= 25
°C
@ Rated V
R
, T
A
= 100
°C
Total Capacitance
C
T
-
-
75
pF
V
R
= 4V, f = 1MHz
Notes:
4. Valid provided that terminals are kept at ambient temperature.
5. Short duration pulse test used to minimize self-heating effect.
0.01
0.1
1.0
10
0
0.2
0.4
0.6
0.8
1.0
I,
I
N
S
T
AN
T
ANE
O
U
S
F
O
R
WA
R
D
C
U
R
R
EN
T
(A
)
F
V , INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics
F
T = 25°C
j
T = 100°C
j
T = 125°C