Single buffer gate with 3-state output, New prod uc t recommended operating conditions – Diodes 74LVCE1G126 User Manual
Page 4

74LVCE1G126
SINGLE BUFFER GATE WITH 3-STATE OUTPUT
74LVCE1G126
Document number: DS32217 Rev. 3 - 2
4 of 14
February 2011
© Diodes Incorporated
NEW PROD
UC
T
Recommended Operating Conditions
(Note 4)
Symbol
Parameter
Min
Max
Unit
V
CC
Operating Voltage
Operating 1.4
5.5
V
Data retention only
1.2
V
V
IH
High Level Input Voltage
V
CC
= 1.4 V to 1.95 V
0.65 X V
CC
V
V
CC
= 2.3 V to 2.7 V
1.7
V
CC
= 3 V to 3.6 V
2
V
CC
= 4.5 V to 5.5 V
0.7 X V
CC
V
IL
Low Level Input Voltage
V
CC
= 1.4 V to 1.95 V
0.35 X V
CC
V
V
CC
= 2.3 V to 2.7 V
0.7
V
CC
= 3 V to 3.6 V
0.8
V
CC
= 4.5 V to 5.5 V
0.3 X V
CC
V
I
Input
Voltage
0
5.5
V
V
O
Output
Voltage
0
V
CC
V
I
OH
High Level Output
Current
Vcc=1.4 V
-3
mA
V
CC
= 1.65 V
-4
V
CC
= 2.3 V
-8
V
CC
= 3 V
-16
-24
V
CC
= 4.5 V
-32
I
OL
Low Level Output
Current
Vcc=1.4 V
3
mA
V
CC
= 1.65 V
4
V
CC
= 2.3 V
8
V
CC
= 3 V
16
24
V
CC
= 4.5 V
32
Δt/ΔV
Input transition rise or fall
rate
V
CC
= 1.4 to 3V
20
ns/V
V
CC
= 3.3 V ± 0.3 V
10
V
CC
= 5 V ± 0.5 V
5
T
A
Operating free-air
temperature
-40 85
ºC