Absolute maximum ratings, Recommended operating conditions – Diodes 74LVC125A User Manual
Page 3

74LVC125A
Document number: DS35265 Rev. 3 - 2
3 of 10
July 2012
© Diodes Incorporated
74LVC125A
Absolute Maximum Ratings
(Note 4)
(@T
A
= +25°C, unless otherwise specified.)
Symbol
Description
Rating
Unit
ESD HBM
Human Body Model ESD Protection
2
KV
ESD CDM
Charged Device Model ESD Protection
1
KV
ESD MM
Machine Model ESD Protection
200
V
V
CC
Supply Voltage Range
-0.5 to 6.5
V
V
I
Input Voltage Range
-0.5 to 6.5
V
V
O
Voltage applied to output in high impedance or I
OFF
state
-0.5 to 6.5
V
V
O
Voltage applied to output in high or low state
-0.3 to V
CC
+0.5
V
I
IK
Input Clamp Current V
I
<0
-50 mA
I
OK
Output Clamp Current V
O
<0
-50 mA
I
O
Continuous output current
±50
mA
I
CC
,
,
I
GND
Continuous current through V
CC
or GND
±100 mA
T
J
Operating Junction Temperature
-40 to +150
°C
T
STG
Storage Temperature
-65 to +150
°C
P
TOT
Total Power Dissipation
500
mW
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should
be within recommend values.
Recommended Operating Conditions
(Note 5)
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Conditions
Min
Max Unit
V
CC
Supply Voltage
1.65
5.50
V
V
I
Input Voltage
0
5.5
V
V
O
Output Voltage
Active Mode
0
V
CC
V
Vcc = 0V; Power Down Mode
0
5.5
V
Δt/ΔV
Input transition rise or fall rate
V
CC
= 1.65V to 2.7V
20
ns/V
V
CC
= 2.7V to 3.6V
10
T
A
Operating free-air temperature
-40
+125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.