Recommended operating conditions, Electrical characteristics – Diodes 74LV132A User Manual
Page 3

74LV132A
Document number: DS35706 Rev. 1 - 2
3 of 9
October 2013
© Diodes Incorporated
Preliminary
74LV132A
Recommended Operating Conditions
(Note 5)
Symbol Parameter
Conditions
Min
Max
Unit
V
CC
Supply Voltage
–
2.0 5.5
V
V
I
Input Voltage
–
0 5.5
V
V
O
Output Voltage
–
0
V
CC
V
I
OH
High-Level Output Current
2.0V –
-50 mA
2.3V to 2.7V
–
-2
μA
3.0V to 3.6V
–
-6
mA
4.5V to 5.5V
–
-12
mA
I
OL
Low-Level Output Current
2.0V –
50
μA
2.3V to 2.7V
–
2
mA
3.0V to 3.6V
–
6
mA
4.5V to 5.5V
–
12
mA
T
A
Operating Free-Air
Temperature
– -40
+125
°C
Note: 5. Unused inputs should be held at Vcc or Ground.
Electrical Characteristics
Symbol Parameter Test
Conditions
V
CC
T
A
= -40 to +85°C
T
A
= -40 to +125°C
Unit
Min Max Min Max
V
T+
Positive Going
Threshold
–
2.5
V
1 1.75 1 1.75
V
–
3.3
V
1.31 2.31 1.31 2.31
–
5.0 V
1.95
3.5
1.95
3.5
V
T-
Negative Going
Threshold
–
2.5
V 0.75 1.5 0.75 1.5
–
–
3.3
V
0.99 2.07 0.99 2.07
–
5.0 V
1.5
3.05
1.5
3.05
V
H
Hysteresis
(V
T+ -
V
T-)
–
2.5
V 0.25 1 0.25 1
V
–
3.3
V
0.33 1.32 0.33 1.32
–
5.0
V 0.5 2 0.5 2
V
OH
High-Level
Output Voltage
I
OH
= -50μA
2.0V to 5.5V
V
CC
-0.1
–
V
CC
-0.1
–
V
I
OH
= -2mA
2.3V 2.0
–
2.0 –
I
OH
= -6mA
3.0V 2.48
–
2.48 –
I
OH
= -12mA
4.5V 3.8
–
3.8 –
V
OL
Low-Level
Output Voltage
I
OL
= 50μA
2.0V to 5.5V
–
0.1 –
0.1
V
I
OL
= 2mA
2.3V –
0.4 –
0.4
I
OL
= 6mA
3.0V –
0.44 –
0.44
I
OL
= 12mA
4.5V –
0.55 –
0.55
I
OFF
Power Down
Leakage Current V
I
or V
O
= 0 to 5.5V
0V –
5 –
5
μA
I
I
Input Current
V
I
=GND or 5.5V
0 to 5.5V
–
±1 –
±1
μA
I
CC
Supply Current
V
I
= GND or V
CC
I
O
=0
5.5V –
20 –
20
μA