Absolute maximum ratings, Recommended operating conditions – Diodes 74HCT138 User Manual
Page 4

74HCT138
Document number: DS35489 Rev. 3 - 2
4 of 10
June 2013
© Diodes Incorporated
74HCT138
Absolute Maximum Ratings
(Note 4)
(@T
A
= +25°C, unless otherwise specified.)
Symbol Description
Rating
Unit
ESD HBM
Human Body Model ESD Protection
2
KV
ESD CDM
Charged Device Model ESD Protection
1
KV
ESD MM
Machine Model ESD Protection
200
V
V
CC
Supply Voltage Range
-0.5 to 7.0
V
V
I
Input Voltage Range
-0.5 to 7.0
V
V
o
Voltage Applied to Output in High or Low State
-0.3 to V
CC
V
I
IK
Input Clamp Current V
I
< -0.5V
-20 mA
I
IK
Input Clamp Current V
I
> V
CC
+ 0.5V
20 mA
I
OK
Output Clamp Current V
O
< -0.5V
-20 mA
I
OK
Output Clamp Current V
O
> V
CC
+ 0.5V
20 mA
I
O
Continuous Output Current
+/- 25
mA
I
CC
Continuous Current Through V
CC
50 mA
I
GND
Continuous Current Through GND
-50
mA
T
J
Operating Junction Temperature
-40 to 150
°C
T
STG
Storage Temperature
-65 to 150
°C
P
TOT
Total Power Dissipation
500
mW
Note:
4. Stresses beyond the absolute maximum may result in immediate failure or reduced reliability. These are stress values and device operation should
be within recommend values.
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Conditions
Min
Max
Unit
V
CC
Supply Voltage
4.5 5.5
V
V
I
Input Voltage
0 Vcc
V
V
O
Output Voltage
Active Mode
0
V
CC
V
t/V
Input transition rise or fall rate
V
CC
= 4.5V
100 ns/V
T
A
Operating free-air temperature
-40 125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.