New prod uc t 74ahcu04, Recommended operating conditions, Electrical characteristics – Diodes 74AHCU04 User Manual
Page 3: Operating characteristics

74AHCU04
Document number: DS35347 Rev. 3 - 2
3 of 8
January 2013
© Diodes Incorporated
NEW PROD
UC
T
74AHCU04
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Conditions Min
Max Unit
V
CC
Supply Voltage
2.0
5.5
V
V
I
Input Voltage
0
5.5
V
V
O
Output Voltage
0
V
CC
V
Δt/ΔV
Input Transition Rise or Fall Rate
V
CC
= 3.0V to 3.6V
100
ns/V
V
CC
= 4.5V to 5.5V
20
T
A
Operating Free-Air Temperature
-40
+125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Test
Conditions
V
CC
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
Unit
Min Max Min Max
V
IH
High-Level Input
Voltage
2.0V 1.7 1.7
V
3.0V 2.4 2.4
5.5V 4.4 4.4
V
IL
Low-Level input
Voltage
2.0V 0.3 0.3
V
3.0
V 0.6 0.6
5.5V 1.1 1.1
V
OH
High-Level Output
Voltage
I
OH
= -50μA
2.0V 1.8 1.8
V
I
OH
= -50μA
3.0V 2.7 2.7
I
OH
= -50μA
4.5V 4.0 4.0
I
OH
= -4mA
3.0V 2.48 2.40
I
OH
= -8mA
4.5V 3.80 3.70
V
OL
Low-Level Output
Voltage
I
OL
= 50μA
2.0V 0.2 0.2
V
I
OL
= 50μA
3.0V 0.3 0.3
I
OL
= 50μA
4.5V 0.5 0.5
I
OL
= 4mA
3.0V 0.44 0.55
I
OL
= 8mA
4.5V 0.44 0.55
I
I
Input Current
V
I
= GND to 5.5V
3.6V ±1 ±2
μA
I
CC
Supply Current
V
I
= GND or V
CC,
I
O
= 0
3.6V 20 40
μA
Operating Characteristics
Parameter
Test
Conditions
V
CC
= 2.0V
V
CC
= 3.3V
V
CC
= 5V
Unit
Typ Typ Typ
C
pd
Power Dissipation
Capacitance per Gate
f = 1MHz
7.9
8.3
9.1
pF
C
i
Input Capacitance
V
i
= V
CC
– or GND
4.0 4.0 4.0 pF