Recommended operating conditions, Electrical characteristics – Diodes 74AHCT594 User Manual
Page 4

74AHCT594
Document number: DS35485 Rev. 2 - 2
4 of 10
www.diodes.com
June 2013
© Diodes Incorporated
74AHCT594
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Conditions
Min
Max
Unit
V
CC
Supply Voltage
4.5 5.5 V
V
I
Input Voltage
0 5.5
V
V
O
Output Voltage
Active Mode
0
V
CC
V
t/V
Input transition Rise or Fall Rate
V
CC
= 4.5V to 5.5V
20 ns/V
T
A
Operating Free-Air Temperature
-40 +125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Test
Conditions
V
CC
T
A
= +25°C
T
A
= -40°C to +85°C T
A
= -40°C to +125°C
Unit
Min Typ Max Min
Max
Min
Max
V
IH
High-level Input
Voltage
4.5V to 5.5V
2.0
2.0
2.0
V
V
IL
Low-level input
voltage
4.5V to 5.5V
0.8
0.8
0.8 V
V
OH
High Level
Output Voltage
I
OH
= -50
μA
4.5V 4.4
4.5
4.4
4.4
V
I
OH
= -8mA
4.5V 3.94
3.80
3.70
V
OL
Low-level
Output Voltage
I
OL
= 50
μA
4.5V
0 0.1
0.1
0.1
V
I
OL
= 8mA
4.5V
0.36
0.44
0.55
I
I
Input Current
V
I
= GND or 5.5V
0V to 5.5V
0.1 ±0.1
± 1
± 2
μA
I
CC
Supply Current
V
I
= GND or V
CC
I
O
= 0
5.5V
4.0
40
80
μA
∆I
CC
Additional
Supply Current
per Input
V
I
= V
CC
-2.1V
I
O
= 0
4.5V to 5.5V
1.35
1.5
1.5 mA
C
i
Input
Capacitance
V
i
= V
CC
or GND
5.5V
3.5 10
10
10 pF