74AHC126
Document number: DS35346 Rev. 3 - 2
3 of 9
January 2013
© Diodes Incorporated
NEW PROD
UC
T
74AHC126
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Conditions Min
Max Unit
V
CC
Supply Voltage
2.0
5.5
V
V
I
Input Voltage
0
5.5
V
V
O
Output Voltage
0
V
CC
V
Δt/ΔV
Input Transition Rise or Fall Rate
V
CC
= 3.0V to 3.6V
100
ns/V
V
CC
= 4.5V to 5.5V
20
T
A
Operating Free-Air Temperature
-40
+125
°C
Note:
5. Unused inputs should be held at V
CC
or Ground.
Electrical Characteristics
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter
Test
Conditions
V
CC
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
Unit
Min Max Min Max
V
IH
High-Level
Input Voltage
2.0V
1.5 1.5
V
3.0V
2.1 2.1
5.5V
3.85 3.85
V
IL
Low-Level Input
Voltage
2.0V 0.5 0.5
V
3.0V 0.9 0.9
5.5V 1.65 1.65
V
OH
High-Level
Output Voltage
I
OH
= -50μA
2.0V
1.9 1.9
V
I
OH
= -50μA
3.0V
2.9 2.9
I
OH
= -50μA
4.5V
4.4 4.4
I
OH
= -4mA
3.0V
2.48 2.40
I
OH
= -8mA
4.5V
3.80 3.70
V
OL
Low-Level
Output Voltage
I
OL
= 50μA
2.0V 0.1 0.1
V
I
OL
= 50μA
3.0V 0.1 0.1
I
OL
= 50μA
4.5V 0.1 0.1
I
OL
= 4mA
3.0V 0.44 0.55
I
OL
= 8mA
4.5V 0.44 0.55
I
OZ
Z State
Leakage
Current
V
O
= 0 to 5.5V
V
I
= GND or 5.5V
5.5V ±2.5 ±10
μA
I
I
Input Current
V
I
= GND to 5.5V
3.6V ±1 ±2
μA
I
CC
Supply Current
V
I
= GND or V
CC
, I
O
= 0
3.6V 20 40
μA