Recommended operating conditions, Electrical characteristics – Diodes 74LVC2G07 User Manual
Page 3
74LVC2G07
Document number: DS35162 Rev. 5 - 2
3 of 11
October 2013
© Diodes Incorporated
74LVC2G07
Recommended Operating Conditions
(Note 5) (@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Min
Max
Unit
V
CC
Operating Voltage
Operating 1.65
5.5
V
Data retention only
1.5
V
V
IH
High-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.65 X V
CC
V
V
CC
= 2.3 V to 2.7V
1.7
V
CC
= 3V to 3.6V
2
V
CC
= 4.5V to 5.5V
0.7 X V
CC
V
IL
Low-Level Input Voltage
V
CC
= 1.65V to 1.95V
0.35 X V
CC
V
V
CC
= 2.3V to 2.7V
0.7
V
CC
= 3V to 3.6V
0.8
V
CC
= 4.5V to 5.5V
0.3 X V
CC
V
I
Input Voltage
0 5.5 V
V
O
Output Voltage
0
V
CC
V
I
OL
Low-Level Output Current
V
CC
= 1.65V
4
mA
V
CC
= 2.3V
8
V
CC
= 3V
16
24
V
CC
= 4.5V
32
Δt/ΔV
Input transition rise or fall rate
V
CC
= 1.8V ± 0.15V, 2.5V ± 0.2V
20
ns/V
V
CC
= 3.3V ± 0.3V
10
V
CC
= 5V ± 0.5V
10
T
A
Operating free-air temperature
-40 125 °C
Note: 5. Unused inputs should be held at V
CC
or Ground.
Electrical Characteristics
Symbol
Parameter
Test Conditions
V
CC
-40°C to +85°C
-40°C to +125°C
Min
Max
Min
Max
Unit
V
OL
Low Level Output Voltage
I
OL
= 100μA
1.65V to 5.5V
0.1
0.1
V
I
OL
= 4mA
1.65V
0.45
0.70
I
OL
= 8mA
2.3V
0.3
0.45
I
OL
= 16mA
3V
0.4
0.60
I
OL
= 24mA
0.55
0.80
I
OL
= 32mA
4.5V
0.55
0.80
I
I
Input Current
V
I
= 5.5V or GND
0 to 5.5V
± 5
± 20
μA
I
OZ
Z State Leakage Current
V
O
= 0 to 5.5V
3.6V
± 10
± 10
μA
I
OFF
Power Down Leakage Current
V
I
or V
O
= 5.5V
0V
± 10
± 20
μA
I
CC
Supply Current
V
I
= 5.5V or GND, I
O
= 0
1.65V to 5.5V
10
40
μA
ΔI
CC
Additional Supply Current
Input at V
CC
–0.6V
3V to 5.5V
500
5000
μA