Apx4558, New prod uc t pin descriptions, Absolute maximum ratings – Diodes APX4558 User Manual
Page 2: Recommended operating conditions

APX4558
DUAL CHANNEL LOW NOISE GENERAL PURPOSE
OPERATIONAL AMPLIFIER
APX4558
Document number: DS35022 Rev. 4 - 2
2 of 10
January 2011
© Diodes Incorporated
NEW PROD
UC
T
Pin Descriptions
Pin #
Name
Description
1 1OUT
Amplifier
1
output
2
1IN-
Amplifier 1 inverting input
3
1IN+
Amplifier 1 non-inverting input
4 V
CC-
Negative supply pin for amplifier 1 and amplifier 2
5
2IN+
Amplifier 2 non-inverting input
6
2IN-
Amplifier 2 inverting input
7 2OUT
Amplifier
2
output
8 V
CC+
Positive supply pin for amplifier 1 and amplifier 2.
Absolute Maximum Ratings
(Note 2)
Symbol
Parameter
Rating
Unit
V
CC+
Supply voltage (Note 3)
18
V
V
CC-
-18
V
ID
Differential input voltage (Note 4)
±30
V
V
I
Input voltage (any input) (Note 3, 5)
±15
V
Duration of output short circuit to ground, one
amplifier at a time (Note 6)
Unlimited
T
J
Junction Temperature (Note 7)
150
°C
T
STG
Storage Temperature
-65 to 150
°C
Notes:
2. Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
3. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–.
4. Differential voltages are at IN+ with respect to IN–.
5. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
6. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
7. Maximum power dissipation is a function of T
J
(max),
θ
JA
,
and T
A
. The maximum allowable power dissipation at any allowable ambient temperature
is P
D
= (T
J
(max) – T
A
)/
θ
JA
. Operating at the absolute maximum T
J
of 150
°C can affect reliability.
Recommended Operating Conditions
Symbol
Parameter
Min
Max
Unit
V
CC+
Supply voltage (Note 3)
5 15
V
V
CC-
-5 -15
T
A
Operating Ambient
Temperature Range
APX4558 0
70
°C
APX4558I -40
105