beautypg.com

Ats177 – Diodes ATS177 User Manual

Page 4

background image

ATS177

SINGLE OUTPUT HALL EFFECT LATCH

ATS177

Document number: DS31055 Rev. 6 - 2

4 of 9

www.diodes.com

July 2010

© Diodes Incorporated

Magnetic Characteristics

(T

A

= 25

°C, Note 3)

(1mT=10 Gauss)

A grade

Symbol

Parameter

Min

Typ.

Max

Unit

Bops(south pole to brand side)

Operation Point

5

-

70

Gauss

Brps(south pole to brand side)

Release Point

-70

-

-5

Gauss

Bhy(|Bopx|-|Brpx|) Hysteresis

- 80 -

Gauss

B grade

Symbol

Parameter

Min

Typ.

Max

Unit

Bops(south pole to brand side)

Operation Point

-

-

100

Gauss

Brps(south pole to brand side)

Release Point

-100

-

-

Gauss

Bhy(|Bopx|-|Brpx|) Hysteresis

-

80 -

Gauss

Notes: 3. Magnetic characteristics may vary with supply voltage, operating temperature and after soldering.

12

10

8

6

4

2

OP

ON

OFF

RP

Output Voltage in Volts

-200

200

100

-100

0

Magnetic Flux Density in Gauss

DO

Vsat

Typical Magnetic Switch Point vs. Temperuture

-50

0

50

100

-20

25

80

100

Temperature (

o

C)

Fl

u

x D

e

n

s

ity

(B

)

Bop

Brp

Bhys