Absolute Maximum Ratings
(Note 1)
Symbol
Parameter
Value
Unit
V
CC
Supply Voltage
20
V
I
CC
Supply Current (Fault)
5
mA
I
OUT
Output Current (Continuous)
25
mA
P
D
Power Dissipation
TO-92S-3
400
mW
SOT-23-3
230
T
A
Operation Temperature
-50 to +150
ºC
T
STG
Storage Temperature
-65 to +150
ºC
T
J
(Max)
Maximum Junction Temperature
+165
ºC
ESD
ESD (Human Body Model)
6000
V
Note 1: St
resses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “Recommended Operating Conditions” is not implied.
Exposure to “Absolute Maximum Ratings” for extended periods may affect device reliability.
Recommended Operating Conditions
Symbol
Parameter
Min
Max
Unit
V
CC
Supply Voltage
3.5
20
V
T
A
Operating Ambient Temperature
-40
+125
ºC