Absolute Maximum Ratings
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Rating
Unit
ESD HBM
Human Body Model ESD Protection
3
kV
ESD MM
Machine Model ESD Protection
300
V
V
IN
Input Voltage
6.5
V
V
OUT
Output Voltage
V
IN
+0.3
V
V
EN ,
V
FLG
Enable Voltage
6.5
V
I
LOAD
Maximum Continuous Load Current
Internal Limited
A
T
J(MAX)
Maximum Junction Temperature
150
°C
T
ST
Storage Temperature Range (Note 4)
-65 to +150
°C
Caution: Stresses greater than the 'Absolute Maximum Ratings' specified above, may cause permanent damage to the device. These are stress ratings only;
functional operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be
affected by exposure to absolute maximum rating conditions for extended periods of time.
Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling
and transporting these devices
Note:
4. UL Recognized Rating from -30°C to +70°C (Diodes qualified
T
ST
from -65°C to +150°C)
Recommended Operating Conditions
(@T
A
= +25°C, unless otherwise specified.)
Symbol Parameter Min
Max
Units
V
IN
Input voltage
2.7
5.5
V
I
OUT
Output Current
0
1.5
A
V
IL
EN Input Logic Low Voltage
0
0.8
V
V
IH
EN Input Logic High Voltage
2
V
IN
V
T
A
Operating Ambient Temperature
-40
+85
C