Water hardness
Water softener
adjustment
German
degrees
(°dH)
French
degrees
(°fH)
mmol/l
Clarke
degrees
Manual
Elec-
tronic
11 - 14
19 - 25
1.9 - 2.5
13 - 17
1
3
4 - 10
7 - 18
0.7 - 1.8
5 - 12
1
2
< 4
< 7
< 0.7
< 5
1
2)
1
2)
1) Factory position.
2) Do not use salt at this level.
You must adjust the water soft-
ener manually and electronically.
Manual adjustment
Turn the water hardness dial to the posi-
tion 1 or 2.
Electronic adjustment
1. Press the on/off button to activate
the appliance. Make sure that the ap-
pliance is in setting mode, refer to
‘Setting and starting a programme’.
2. Press and hold, at the same time,
button
and button
until
the indicators of buttons
,
and
start to flash.
3.
Press button
.
• The indicators of buttons
and
go off.
•
The indicator of button
con-
tinues to flash.
• The current setting of the water
softener is indicated by intermit-
tent acoustic signals and the flash-
ing of the end indicator.
– E.g. 5 acoustic signals and 5
flashes + pause + 5 acoustic sig-
nals and 5 flashes = level 5.
4.
Press button
again and again
to change the setting. Each time you
press the button you select the next
level.
5. Deactivate the appliance to confirm
the setting.
ENGLISH