Preliminary datasheet, Recommended operating conditions – Diodes AP2160 User Manual
Page 4
Preliminary Datasheet
Ultra Low Output Voltage Linear N-FET Controller AP2160
Jan. 2012 Rev. 1. 0 BCD Semiconductor Manufacturing Limited
4
Absolute Maximum Ratings (Note 1)
Parameter Symbol
Value
Unit
VCC to GND
V
CC
-0.3 to 7
V
DRV to GND
V
DRV
-0.3
to
V
CC
+0.3 V
POK to GND
V
POK
-0.3
to
V
CC
+0.3 V
FB to GND
V
FB
-0.3
to
V
CC
+0.3 V
EN to GND
V
EN
-0.3
to
V
CC
+0.3 V
Operating Junction Temperature
T
J
150 ºC
Power Dissipation (25ºC)
P
D
0.4 W
Operating Temperature Range
T
OPR
-40
to
85 ºC
Storage Temperature Range
T
STG
-65
to
150 ºC
Lead Temperature (Soldering, 10
Seconds)
T
LEAD
260 ºC
ESD (Machine Model)
200 V
ESD (Human Body Model)
2000 V
Note 1: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to
the device. These are stress ratings only, and functional operation of the device at these or any other conditions
beyond those indicated under “Recommended Operating Conditions” is not implied. Exposure to “Absolute
Maximum Ratings” for extended periods may affect device reliability.
Recommended Operating Conditions
Parameter
Symbol Min Max
Unit
Supply Voltage (between VCC and GND)
V
CC
4.5 5.5
V
System Input Voltage (between VIN and GND)
V
IN
0.5 5.5
V
Ambient Operating Temperature Range
T
A
-40 85
°C