New prod uc t absolute maximum ratings, Package thermal data, Recommended operating conditions – Diodes ZXRD060 User Manual
Page 3

ZXRD060
0.6V DUAL ADJUSTABLE PRECISION SHUNT REGULATOR
ZXRD060
Document number: DS35359 Rev. 4 - 2
3 of 12
August 2011
© Diodes Incorporated
A Product Line of
Diodes Incorporated
NEW PROD
UC
T
Absolute Maximum Ratings
(Voltages to GND Unless Otherwise Stated)
Symbol
Parameter
Rating
Unit
V
IN
IN Voltage relative to GND
20
V
V
OUT
OUT Voltage relative to GND
20
V
V
FB
FB Voltage relative to GND
20
V
P
GND
PGND Voltage relative to GND
-0.3 to +0.3
V
I
OUT
OUT Pin Current
20
mA
T
J
Operating Junction Temperture
-40 to 150
°C
T
ST
Storage Temperature
55 to 150
°C
Stresses greater than the 'Absolute Maximum Ratings' specified above, may cause permanent damage to the device. These are stress ratings only; functional
operation of the device at these or any other conditions exceeding those indicated in this specification is not implied. Device reliability may be affected by exposure
to absolute maximum rating conditions for extended periods of time.
Semiconductor devices are ESD sensitive and may be damaged by exposure to ESD events. Suitable ESD precautions should be taken when handling and
transporting these devices.
Package Thermal Data
Package
θ
JA
P
DIS
T
A
= 25°C, T
J
= 150°C
DFN2626P10 152°C/W
0.8W
Recommended Operating Conditions
Symbol
Parameter
Min
Max
Units
V
IN
IN Voltage Range (0 to 125°C)
2
18
V
V
IN
IN Voltage Range (-40 to 0°C)
2.2
18
V
OUT
OUT Voltage Range
0.2
18
I
OUT
OUT Pin Current
0.3
15
mA
T
A
Operating Ambient Temperature Range
-40
125
°C