Electrical characteristics – Diodes ZXMS6006DG User Manual
Page 5
![background image](/manuals/305671/5/background.png)
ZXMS6006DG
Document number: DS35142 Rev. 1 - 2
5 of 9
December 2010
© Diodes Incorporated
ZXMS6006DG
ADVAN
CE I
N
F
O
RM
ATI
O
N
A Product Line of
Diodes Incorporated
IntelliFET
®
is a trademark of Diodes Incorporated, registered in the United States and other jurisdictions worldwide.
Electrical Characteristics
@T
A
= 25°C unless otherwise specified
Characteristic Symbol
Min
Typ
Max
Unit
Test
Condition
Static Characteristics
Drain-Source Clamp Voltage
V
DS(AZ)
60 65 70 V
I
D
= 10mA
Off State Drain Current
I
DSS
- - 1
µA
V
DS
= 12V, V
IN
= 0V
- - 2
V
DS
= 36V, V
IN
= 0V
Input Threshold Voltage
V
IN(th)
0.7 1 1.5 V
V
DS
= V
GS
, I
D
= 1mA
Input Current
I
IN
- 60 100
μA
V
IN
= +3V
- 120 200
V
IN
= +5V
Input Current While Over Temperature Active
-
-
-
400
μA
V
IN
= +5V
Static Drain-Source On-State Resistance
R
DS(on)
- 85 125
m
Ω
V
IN
= +3V, I
D
= 1A
- 75 100
V
IN
= +5V, I
D
= 1A
Continuous Drain Current (Note 4)
I
D
2.0 -
-
A
V
IN
= 3V; T
A
= 25
°C
2.2 -
-
V
IN
= 5V; T
A
= 25
°C
Continuous Drain Current (Note 5)
2.6 -
-
V
IN
= 3V; T
A
= 25
°C
2.8 -
-
V
IN
= 5V; T
A
= 25
°C
Current Limit (Note 7)
I
D(LIM)
4 8 -
A
V
IN
= +3V
6 13 -
V
IN
= +5V
Dynamic Characteristics
Turn On Delay Time
t
d(on)
- 8.6 -
μs
V
DD
= 12V, I
D
= 1A, V
GS
= 5V
Rise Time
t
r
- 18 -
Turn Off Delay Time
t
d(off)
- 34 -
Fall Time
f
f
- 15 -
Over-Temperature Protection
Thermal Overload Trip Temperature (Note 8)
T
JT
150 175
-
°C
-
Thermal Hysteresis (Note 8)
f
f
- 10 -
°C
-
Notes: 7. The drain current is restricted only when the device is in saturation (see graph ‘typical output characteristic’). This allows the device to be used in the fully
on state without interference from the current limit. The device is fully protected at all drain currents, as the low power dissipation generated outside
saturation makes current limit unnecessary.
8. Over-temperature protection is designed to prevent device destruction under fault conditions. Fault conditions are considered as “outside” normal
operating range, so this part is not designed to withstand over-temperature for extended periods..