Electrical characteristics – Diodes PDU620CT User Manual
Page 2

DS30622 Rev. 4 - 2
2 of 4
PDU620CT
PowerDI is a trademark of Diodes Incorporated.
www.diodes.com
0
0.4
0.8
1.2
I
,
INST
ANT
A
NE
O
US
F
O
R
W
ARD
CURRENT
(A)
F
V , INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics, per element
F
1
10
100
1.6
1m
10m
100m
T = -65°C
j
T = 175°C
j
T = 150°C
j
T = 125°C
j
T = 85°C
j
T = 25°C
j
0
50
100
150
200
V , INSTANTANEOUS REVERSE VOLTAGE (V)
Fig. 2 Typical Reverse Characteristics, per element
R
0.1
1
10
100
1,000
0.001
0.01
T = -65°C
j
T = 175°C
j
T = 25°C
j
T = 150°C
j
T = 85°C
j
T = 125°C
j
C
,
T
O
T
A
L
C
AP
ACIT
ANCE
(pF)
T
V , REVERSE VOLTAGE (V)
Fig. 3 Typical Total Capacitance vs. Reverse Voltage,
per element
R
0
30
60
90
120
150
180
210
240
0
10
20
30
40
f = 1MHz
0
1.5
0.75
2.25
3.75
3.0
0
25
50
75
125
100
150
175
I,
D
C
F
O
R
W
ARD
CURRENT
(A)
F
T , AMBIENT TEMPERATURE (°C)
Fig. 4 DC Forward Current Derating, per element
A
Note 3
Note 2
Electrical Characteristics
@ T
A
= 25
°C unless otherwise specified
Characteristic
Symbol
Value
Unit
Test Condition
Minimum Reverse Breakdown Voltage (Note 5)
V
(BR)R
200
V
I
R
= 5
mA
Maximum Forward Voltage per element
V
FM
1.00
0.96
1.20
1.13
V
I
F
= 3A, T
S
= 25
°C
I
F
= 3A, T
S
= 125
°C
I
F
= 6A, T
S
= 25
°C
I
F
= 6A, T
S
= 125
°C
Maximum Reverse Leakage Current per element
(Note 5)
I
RM
5
250
mA
T
S
= 25
°C, V
R
= 200V
T
S
= 125
°C, V
R
= 200V
Maximum Reverse Recovery Time
t
rr
25
ns
I
F
= 0.5A, I
R
= 1.0A
I
RR
= 0.25A (See figure 7)
Notes:
5. Short duration test pulse used to minimize self-heating effect.