Maximum ratings (per leg), Thermal characteristics (per leg), Electrical characteristics (per leg) – Diodes SBL1060CTP User Manual
Page 2: Sbl1060ctp

SBL1060CTP
Document number: DS31458 Rev. 7 - 2
2 of 4
April 2011
© Diodes Incorporated
SBL1060CTP
Maximum Ratings (Per Leg)
@T
A
= 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic Symbol
Value
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
RM
60 V
Average Rectified Output Current
(Per Leg)
(Total)
I
O
5
10
A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single Half Sine-Wave Superimposed on Rated Load
I
FSM
110 A
Isolation Voltage
From Terminal Heatsink t = 1 min.
V
AC
2000 V
Thermal Characteristics (Per Leg)
Characteristic Symbol
Value
Unit
Typical Thermal Resistance Junction to Case
R
θJC
3
°C/W
Operating and Storage Temperature Range
T
J
, T
STG
-65 to +150
ºC
Electrical Characteristics (Per Leg)
@T
A
= 25°C unless otherwise specified
Characteristic Symbol
Min
Typ
Max
Unit
Test
Condition
Forward Voltage Drop
V
F
-
-
-
0.57
0.7
0.62
V
I
F
= 5A, T
J
= 25ºC
I
F
= 5A, T
J
= 125ºC
Leakage Current (Note 2)
I
R
-
-
-
-
0.5
50
mA
V
R
= 60V, T
J
= 25ºC
V
R
= 60V, T
J
= 100ºC
Notes:
2. Short duration pulse test used to minimize self-heating effect.
0
300
600
900
0.01
0.1
1
10
I,
I
N
S
T
A
N
T
A
N
E
O
U
S
F
O
R
WA
R
D
C
U
R
R
E
N
T
(A
)
F
Fig. 1 Typical Forward Characteristics
V , INSTANTANEOUS FORWARD VOLTAGE (mV)
F
T = 25°C
A
T = -55°C
A
T = 85°C
A
T = 125°C
A
T = 150°C
A
0
10
20
30
40
50
60
Fig. 2 Typical Reverse Characteristics
V , INSTANTANEOUS REVERSE VOLTAGE (V)
R
1
10
100
1,000
10,000
100,000
I
, INS
T
AN
T
ANE
O
U
S
R
EVE
R
SE
C
U
R
R
EN
T
(µ
A
)
R
T = 25°C
A
T = 85°C
A
T = 125°C
A
T = 150°C
A