beautypg.com

Operational checks – Armasight NRWVULCAN439DB1 Vulcan 4.5X Gen3 Bravo MG - Compact Professional 4.5x Night Vision Rifle Scope User Manual

Page 29

background image

29

SEq

NO.

LOCATION ITEM TO

CHECK/SERVICE

PROCEDURE

NOT FULLY MISSION

CAPABLE IF ...

4

Eyecup

Inspect for dirt and dust. Inspect for cracked, torn, bent, bro-

ken, or improperly fitting eyecup.

Cup is torn or cut.

5

Battery Compart-

ment/ Cap / Battery

Adapter

Check to make sure the battery adapter is present. Check for

corrosion, cap damage or retainer breaks. Check O-ring for

cuts or damage.

Retainer is broken. Cap, O-ring or battery

adapter is damaged or missing.

6

Switch

Check for operation (without battery).

Switch is inoperative.

7

Lenses

Inspect for cleanliness, scratches, chips or cracks. Clean as

required.

Chipped or cracked. Scratches hinder vi-

sion through the Vulcan.

8

Photoreceiver

Inspect for cleanliness, scratches. Clean as required.

Photoreceiver is damaged.

9

Eyepiece Ring

Check to ensure there is free rotation through full range of

travel.

Ring is inoperative.

10

Gain Control Knob

Check to ensure there is free rotation through full range of

travel.

Knob is inoperative.

Knob is missing

11

Reticle Brightness

Adjustment Knob

Check to ensure there is free rotation through full range of

travel.

Knob is inoperative.

Knob is missing

12

Advanced Wireless

Remote Control

Check for damage.
Check Velcro tape for wear.

Damaged. Unit or tape is missing.

13

Mount

Inspect for damage or corrosion, and for missing parts.

Check for proper operation.

Damaged. Some parts are missing.

Clamping device is inoperative.

14

IR850 Body, Mount

Inspect for damage and missing parts. Check for proper

operation.

Damaged. Missing parts. Mount is inop-

erative.

15

IR850 Battery Cap,

Power Switch

Check O-ring for damage. Check for proper operation.

O-ring is damaged or missing. Switch is

inoperative.

16

IR850 Lens

Inspect for cleanliness, scratches, chips or cracks. Clean as

required. Check to ensure there is free rotation through the

full range of travel (1 turn).

Lens is chipped or cracked. Lens is stick-

ing or too loose when turned.

OPERATIONAL CHECKS

CAUTION:

The objective lens cap has an optical filter, which allows operational testing of the Vulcan in daylight. Activate the Vulcan in daylight

only with the objective lens cap on or in dark conditions.
NOTE:

Daylight checks are described below.

17

Vulcan Switch

Insert the battery. Remove the output lens cap. Close the

photoreceiver by flipping up the pivotal shutter. Turn the

switch to ON. Look for green glow (after a slight delay) in

viewing area.

No green glow.

Open photoreceiver by flipping the pivotal shutter down.

Look through the output lens and wait about 20 seconds for

the green glow to disappear.

Green glow is present, red glow is ab-

sent.

18

Remote Control

Put the unit in STB mode. Press and hold the remote control

button. Look for the green glow in output lens. Release the

button. Turn the device OFF.

Green glow is absent.

19

Eyepiece Ring

Turn the device ON. Rotate the eyepiece ring to ensure it

adjusts the diopter.

Ring does not adjust the diopter.

20

Gain Control Knob

(only MG models)

Rotate the gain control knob to ensure it changes the

screen’s brightness.

Knob does not adjust the screen’s bright-

ness.

21

Reticle Brightness

Adjustment Knob

Rotate the reticle brightness adjustment knob to ensure it

changes the reticles brightness.

Knob does not adjust the reticles bright-

ness.

22

Viewed Image

Check for flickering, flashing, bright spots, edge glow, shad-

ing, or excessive fixed-pattern noise (honeycomb).

Excessive cosmetic defects or fixed pat-

tern noise is present.

23

IR850

Insert the battery. Mount the IR850 onto the Vulcan. Turn on

the IR850. Direct the radiated beam at a wall from a distance

of about 5m. Look through the Vulcan. A square of light

should appear on the wall.

No light appears on the wall.

TABLE 4-1. CONTINUED