Checking the drives for data consistency -27, 5 checking the drives for data consistency, Using the check consistency command – Asus P9D-I User Manual
Page 117: Asus p9d-i

ASUS P9D-I
5-27
2.
The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press
Virtual Drive
sub-menu then press
5.2.5
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the
Objects > Adapter menu.
The
Check Consistency command is available only for virtual drives included in a RAID 1
or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the
Check Consistency command:
1.
From the
Management Menu, select Check Consistency then press
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011
BIOS Version A.11.02090932R
CC of VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
SPACE-(De)Select, F10-Initialize
LSI Software RAID Configuration Utility Ver C.05 Oct 26,2011
BIOS Version A.11.02090932R
Select VD
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
Easy Configuration - ARRAY SELECTION MENU
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64KB ONLINE
Virtual Drive 0
Virtual Drives