2 bmc network configuration, Bmc network configuration -38, Configuration address source [previous state – Asus RS720-E7/RS12 User Manual
Page 104
5-38
Chapter 4: BIOS setup
5.5.2
BMC network configuration
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Server Mgmt
Select to configure LAN
channel parameters
statically or dynamically(by
BIOS or BMC). Unspecified
option will not modify any
BMC network parameters
during BIOS phase
BMC network configuration
DM_KAN1
DM_LAN1 IP Address in BMC: 192.168.001.001
DM_LAN1 Subnet Mask in BMC:
255.255.255.000
DM_LAN1 Gateway Address in BMC : 000.000.000.000
DM_LAN1 MAC Address in BMC:
00.CE.01.87.72.A0
DM_LAN1 Address Source in BMC: Static Mode
Configuration Address source [Previous State]
Lan1
Lan1 IP Address in BMC:
192.168.001.002
Lan1 Subnet Mask in BMC:
255.255.255.000
Lan1 Gateway Address in BMC: 000.000.000.000
Lan1 MAC Address in BMC:
00.CE.01.87.72.A0
Lan1 Address Source in BMC:
Static Mode
Configuration Address source [Previous State]
→←:
Select Screen
↑↓:
Select Item
Enter: Select Item
+/-: Change Opt.
F1: General Help
F2: Previous Values
F5: Optimized Defaults
F10: Save & Exit
ESC: Exit
Version 2.15.1219. Copyright (C) 2011 American Megatrends, Inc.
Configuration Address source [Previous State]
Select to configure LAN channel parameters statically or dynamically(by BIOS
or BMC). Unspecified option will not modify any BMC network parameters during
BIOS phase.
Configuration options: [Previous State] [Static Mode] [DHCP Mode]
The following items appears only when you set Configuration Address source
to [Static Mode].
Station IP address [0.0.0.0]
Allows to input Station IP address.
Subnet mask [0.0.0.0]
Allows to input Subnet mask.
Gateway IP address [0.0.0.0]
Allows to input Gateway IP address.