Procedure – Asus ASMB6-iKVM User Manual
Page 77
ASUS ASMB6-iKVM
4-15
Procedure:
1. Click the Event Filter Tab to configure the event filters in the available slots
2. To Add an Event Filter entry, select a free slot and click Add to open the Add
event Filter entry Page. A sample screenshot of Add Event Filter Page is in
seen the screenshot below.
3. In the Event Filter Configuration section,
•
PEF ID displays the ID for configured PEF entry (read-only).
•
In filter configuration, check the box to enable the PEF settings.
•
In Event Severity, select any one of the Event severity from the list.
4. In the Filter Action configuration section,
•
Event Filter Action is a mandatory field and checked by default, which enable
PEF Alert action (read-only).
•
Select any one of the Power action either Power down, Power reset or Power
cycle from the drop down list
•
Choose any one of the configured alert policy number from the drop down
list.
Alert Policy has to be configured - under Configuration->PEF->Alert Policy.
5. In the Generator ID configuration section,
•
Check Generator ID Data option to fill the Generator ID with raw data.
•
Generator ID 1 field is used to give raw generator ID1 data value.
•
Generator ID 2 field is used to give raw generator ID2 data value.
In RAW data field, to specify hexadecimal value prefix with '0x'.