beautypg.com

5 chassis q-fan control [enabled, 6 anti surge support [enabled, Chassis q-fan control [enabled] -23 – Asus P8H61-M LK R2.0 User Manual

Page 61: Anti surge support [enabled] -23

background image

ASUS P8H61-M LK R2.0

2-23

2.6.6

Anti Surge Support [Enabled]

This item allows you to enable or disable the Anti Surge function.
Configuration options: [Disabled] [Enabled]

2.6.5

Chassis Q-Fan Control [Enabled]

Chassis Q-Fan Control [Enabled]

[Disabled]

Disables the Chassis Q-Fan control feature.

[Enabled]

Enables the Chassis Q-Fan control feature.

Chassis Fan Speed Low Limit [600 RPM]

This item appears only when you enable the Chassis Q-Fan Control feature and allows you

to disable or set the chassis fan warning speed.

Configuration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]

Chassis Fan Profile [Standard]
This item appears only when you enable the Chassis Q-Fan Control feature and

allows you to set the appropriate performance level of the chassis fan.

[Standard]

Sets to [Standard] to make the chassis fan automatically adjust

depending on the chassis temperature.

[Silent]

Sets to [Silent] to minimize the fan speed for quiet chassis fan

operation.

[Turbo]

Sets to [Turbo] to achieve maximum chassis fan speed.

[Manual]

Sets to [Manual] to assign detailed fan speed control parameters.

The following four items appear only when you set Chassis Fan Profile to [Manual].

Chassis Upper Temperature [70]

Use the <+> and <-> keys to adjust the upper limit of the CPU temperature.

The values range from 40ºC to 90ºC.
Chassis Fan Max. Duty Cycle(%) [100]

Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle.

The values range from 60% to 100%. When the chassis temperature

reaches the upper limit, the chassis fan will operate at the maximum duty

cycle.
Chassis Lower Temperature [40]

Displays the lower limit of the chassis temperature.
CPU Fan Min. Duty Cycle(%) [60]

Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle.

The values range from 60% to 100%. When the chassis temperature is

under 40ºC, the chassis fan will operate at the minimum duty cycle.